Products
           Application
         EMC
         Radiation Emission
         EMS
         Conducted Emission
         EMI&EMS
           Standard
  • Products
  • Home > Products > Application > High Voltage Battery Pack Load HVL-10kW
High Voltage Battery Pack Load HVL-10kW
< >

Description

HVL-6kW,
HVL-8kW,
HVL-10kW,
HVL-XXkW,
不建议定制功率过⼤的HVL系列产品

Function

Max load voltage: 1kV, the cable access is fully covered with insulation material and fixed with a pressure plate, the material of the pressure plate is copper-nickel plating, and a cable with max diameter of 20mm can be fixed;
Power: test power can be customized;
Each group of loads has independent ammeters and switches, which can be used in a single group or multiple groups according to actual needs;
The control method is manual, semi-automatic, or automatic;
Each group of loads has independent space, and each group of loads is divided by a heat insulation layer, which can effectively isolate the mutual influence of heating devices during work and prolong the working life of heating devices;
Each group of load has independent temperature controller and controls 2 axial-flow exhaust fans, which can ensure the timely discharge of heat during the test. The factory operating temperature is set to 30°C, which can also be adjusted by itself in a more practical range of 0 ~ 50°C;
The working voltage of axial-flow exhaust fan is 220V AC (powered by laboratory indoor power supply), the fan is all-metal structure, can run at high temperature for a long time;
The box material is stainless steel;
To match the movement of the box on the test bench, casters are installed under the box;
To move in and out of the laboratory, a special trolley is equipped. The plane height of trolley load box: 900mm;
All components of this load box, except the fan, are passive components. The fan motor is an AC motor with excellent EMC performance.

Specification

Basic Config

Option Config

Link